Anker SOLIX F3800 Plus Solar Generator + 400W Solar Panel
DESCRIPTION
- Unprecedented Solar: Max. 3,200W solar input with dual 11-165V MPPT controllers.
- Gas Generator Charging: Compatible with 240V gas generators (6,000W bypass) for extended power outages.
- Expandable Capacity: Starts at 3.84kWh, expandable up to 26.9kWh for increased energy storage.
- Dual-Voltage AC Output: 120V & 240V, 6,000W AC output to power home appliances; expandable up to 12,000W.
- Remote Monitoring & Control: Monitor and manage power settings via the Anker app with Wi-Fi/Bluetooth.
- Long-lasting Performance: 5-year warranty, with an lifespan of 10+ years using EV-grade LFP batteries.
-
EV & RV Charging: Powers EVs and RVs directly through NEMA TT-30P or L14-30 ports.
Plus Outage Power to Outlast Anker SOLIX F3800 Plus
The Most Accessible Whole-Home Backup Power
2× 165V Solar Input, Up to 3,200W

6,000W 240V Generator Charging&Bypass

Auto Backup Before Severe Weather

5-Year Warranty with InfiniPower™

Product Specifications
Anker SOLIX F3800 Plus Solar Generator + 400W Solar Panel Product Specifications


Product Manual
Anker SOLIX F3800 Plus Solar Generator Product Manual
Anker SOLIX PS400 - 400W Solar Panel Product Manual
Product FAQs
Anker SOLIX F3800 Plus FAQs
Q1: Can I use F3800 and F3800 Plus with Double Power Hub at the same time?
Yes.
Q2: Can I use F3800 and F3800 Plus with Home Power Panel at the same time?
Yes.
Q3: Can Anker SOLIX F3800 and F3800 Plus be connected to Home Power Panel, Double Power Hub, and Transfer Switch simultaneously?
Yes.
Q4: When can a generator and F3800 Plus be used together?
You can use a generator and F3800 Plus in the following scenarios:
1. With 240V Generators
- F3800 Plus Only
The generator connects to F3800 Plus's Home Power Panel port. Use the F3800 Plus's L14-30R AC output port to deliver up to 6,000W (240V) or the TT-30R port for up to 3,000W (120V).
- F3800 Plus + Transfer Switch/Inlet Box
The generator connects to F3800 Plus's Home Power Panel port. Use the F3800 Plus's L14-30R AC output port to deliver up to 6,000W (240V).
- F3800 Plus + Home Power Panel
Connect the generator to one of the Home Power Panel's power station ports for up to 6,000W (240V) of generator power.
2. With 120V Generators
- F3800 Plus Only
Connect the generator to F3800 Plus's Home Power Panel port. Use the F3800 Plus's TT-30R AC output port to provide up to 3,000W (120V) max. This setup is an alternative to grid power. Note that the generator must output 120V pure sine wave power with a total harmonic distortion (THD) of less than 5%.
- F3800 Plus + Transfer Switch/Inlet Box
The generator connects to F3800 Plus's Home Power Panel port. Use the F3800 Plus's TT-30R AC output port to deliver up to 3,000W (120V).
Q5: Which of F3800 Plus's AC output ports can be used under different input conditions?
Please review these scenarios to determine how F3800 Plus's output ports can be used.
Condition 1: No AC input power is connected.
Usable AC Output Ports:
• TT-30R (120V~25A)
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 2: When a 120V generator is connected; not plugged into a 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available when connected to the L1 phase. Bypass limit of up to 3,000W. No output when connected to the L2 phase.
Switching Time:
F3800 Plus to Generator: 30 ms.
Generator to F3800 Plus: 50 ms.
Non-Usable AC Output Ports:
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 3: When a 240V generator is connected; not plugged into a 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available with a bypass limit of up to 3,000W.
• L14-30R (120/240V~25A): Output available with a bypass limit of up to 6,000W.
Non-Usable AC Output Ports:
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 4: No generator connection; plugged into 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available. No UPS. Bypass limit of up to 1,440W.
• NEMA 5-20R (3 Leftmost Ports, UPS): Output available with bypass limit of up to 1,440W.
Switching Time: 20 ms
Non-Usable AC Output Ports:
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Rightmost Ports)
Condition 5: Connected to 120V generator; plugged into 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available when connected to the L1 phase wth a bypass limit of up to 3,000W. No output when connected to the L2 phase.
Switching Time:
F3800 Plus to Generator: 30 ms
Generator to F3800 Plus: 50 ms
Non-Usable AC Output Ports:
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 6: Connected to 240V generator; plugged into 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available with a bypass limit of up to 3,000W. If the generator stops outputting, please see Condition 4 above.
• L14-30R (120/240V~25A): Output available with a bypass limit of 6,000W max. If the generator stops outputting, please see Condition 4 above.
Non-Usable AC Output Ports:
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Q6: What should I do when using a solar panel to charge my power station?
Plug solar panels into one of Anker SOLIX F3800 Plus Portable Power Station's 2 solar input ports. Each one supports an 11-165V solar charger with a solar charging connection. The current supports 17A max.
Q7: Can Anker SOLIX F3800 Plus be recharged using rooftop solar panels through Home Power Panel during an outage?
No. When outages occur, directly connect F3800 Plus to your 11-165V solar panels to charge it. Please note that exceeding 165V may cause damage to the solar input ports.
Q8: How do I charge my electric vehicle with Anker SOLIX F3800 Plus?
Double-press the AC Outlet Button to activate EV mode charging. Please make sure to set the charging rate to less than 25A so that Anker SOLIX F3800 Plus can charge your EV, such as a Tesla.
Anker
Anker SOLIX F3800 Plus Portable Power Station Solar Generator (6000W | 3840Wh) + 400W Solar Panel
- Regular price
- $5,698.00
- Sale price
- $3,599.00
Anker SOLIX F3800 Plus Solar Generator + 400W Solar Panel
DESCRIPTION
- Unprecedented Solar: Max. 3,200W solar input with dual 11-165V MPPT controllers.
- Gas Generator Charging: Compatible with 240V gas generators (6,000W bypass) for extended power outages.
- Expandable Capacity: Starts at 3.84kWh, expandable up to 26.9kWh for increased energy storage.
- Dual-Voltage AC Output: 120V & 240V, 6,000W AC output to power home appliances; expandable up to 12,000W.
- Remote Monitoring & Control: Monitor and manage power settings via the Anker app with Wi-Fi/Bluetooth.
- Long-lasting Performance: 5-year warranty, with an lifespan of 10+ years using EV-grade LFP batteries.
-
EV & RV Charging: Powers EVs and RVs directly through NEMA TT-30P or L14-30 ports.
Plus Outage Power to Outlast Anker SOLIX F3800 Plus
The Most Accessible Whole-Home Backup Power
2× 165V Solar Input, Up to 3,200W

6,000W 240V Generator Charging&Bypass

Auto Backup Before Severe Weather

5-Year Warranty with InfiniPower™

Product Specifications
Anker SOLIX F3800 Plus Solar Generator + 400W Solar Panel Product Specifications


Product Manual
Anker SOLIX F3800 Plus Solar Generator Product Manual
Anker SOLIX PS400 - 400W Solar Panel Product Manual
Product FAQs
Anker SOLIX F3800 Plus FAQs
Q1: Can I use F3800 and F3800 Plus with Double Power Hub at the same time?
Yes.
Q2: Can I use F3800 and F3800 Plus with Home Power Panel at the same time?
Yes.
Q3: Can Anker SOLIX F3800 and F3800 Plus be connected to Home Power Panel, Double Power Hub, and Transfer Switch simultaneously?
Yes.
Q4: When can a generator and F3800 Plus be used together?
You can use a generator and F3800 Plus in the following scenarios:
1. With 240V Generators
- F3800 Plus Only
The generator connects to F3800 Plus's Home Power Panel port. Use the F3800 Plus's L14-30R AC output port to deliver up to 6,000W (240V) or the TT-30R port for up to 3,000W (120V).
- F3800 Plus + Transfer Switch/Inlet Box
The generator connects to F3800 Plus's Home Power Panel port. Use the F3800 Plus's L14-30R AC output port to deliver up to 6,000W (240V).
- F3800 Plus + Home Power Panel
Connect the generator to one of the Home Power Panel's power station ports for up to 6,000W (240V) of generator power.
2. With 120V Generators
- F3800 Plus Only
Connect the generator to F3800 Plus's Home Power Panel port. Use the F3800 Plus's TT-30R AC output port to provide up to 3,000W (120V) max. This setup is an alternative to grid power. Note that the generator must output 120V pure sine wave power with a total harmonic distortion (THD) of less than 5%.
- F3800 Plus + Transfer Switch/Inlet Box
The generator connects to F3800 Plus's Home Power Panel port. Use the F3800 Plus's TT-30R AC output port to deliver up to 3,000W (120V).
Q5: Which of F3800 Plus's AC output ports can be used under different input conditions?
Please review these scenarios to determine how F3800 Plus's output ports can be used.
Condition 1: No AC input power is connected.
Usable AC Output Ports:
• TT-30R (120V~25A)
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 2: When a 120V generator is connected; not plugged into a 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available when connected to the L1 phase. Bypass limit of up to 3,000W. No output when connected to the L2 phase.
Switching Time:
F3800 Plus to Generator: 30 ms.
Generator to F3800 Plus: 50 ms.
Non-Usable AC Output Ports:
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 3: When a 240V generator is connected; not plugged into a 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available with a bypass limit of up to 3,000W.
• L14-30R (120/240V~25A): Output available with a bypass limit of up to 6,000W.
Non-Usable AC Output Ports:
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 4: No generator connection; plugged into 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available. No UPS. Bypass limit of up to 1,440W.
• NEMA 5-20R (3 Leftmost Ports, UPS): Output available with bypass limit of up to 1,440W.
Switching Time: 20 ms
Non-Usable AC Output Ports:
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Rightmost Ports)
Condition 5: Connected to 120V generator; plugged into 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available when connected to the L1 phase wth a bypass limit of up to 3,000W. No output when connected to the L2 phase.
Switching Time:
F3800 Plus to Generator: 30 ms
Generator to F3800 Plus: 50 ms
Non-Usable AC Output Ports:
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 6: Connected to 240V generator; plugged into 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available with a bypass limit of up to 3,000W. If the generator stops outputting, please see Condition 4 above.
• L14-30R (120/240V~25A): Output available with a bypass limit of 6,000W max. If the generator stops outputting, please see Condition 4 above.
Non-Usable AC Output Ports:
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Q6: What should I do when using a solar panel to charge my power station?
Plug solar panels into one of Anker SOLIX F3800 Plus Portable Power Station's 2 solar input ports. Each one supports an 11-165V solar charger with a solar charging connection. The current supports 17A max.
Q7: Can Anker SOLIX F3800 Plus be recharged using rooftop solar panels through Home Power Panel during an outage?
No. When outages occur, directly connect F3800 Plus to your 11-165V solar panels to charge it. Please note that exceeding 165V may cause damage to the solar input ports.
Q8: How do I charge my electric vehicle with Anker SOLIX F3800 Plus?
Double-press the AC Outlet Button to activate EV mode charging. Please make sure to set the charging rate to less than 25A so that Anker SOLIX F3800 Plus can charge your EV, such as a Tesla.
- Regular price
- $5,698.00
- Sale price
- $3,599.00
Estimated shipping time
Estimated shipping time
You can typically expect your items to arrive within 4–7 business days, depending on your location and product availability.
What is your Return Policy?
What is your Return Policy?
At TrailQuest Gear, we want every customer to shop with confidence. If something doesn’t go as planned, we’ve made returns and refunds simple and fair. Here’s how it works:
1. Return Window
You can request a return within 30 days of receiving your order. Unfortunately, we’re unable to accept returns after that time frame.
2. Who Pays for Return Shipping?
- If your item arrives damaged, defective, or incorrect, we’ll cover the return shipping cost.
- If you’re returning an item because you changed your mind, you’ll be responsible for return shipping fees.
3. Damaged or Defective Items
Received something broken or not working properly? Contact us within 30 days. We’ll provide a prepaid return label and once the item is returned and inspected, we’ll issue either a full refund or a replacement—including any original shipping costs.
4. Changed Your Mind?
If you no longer want the item, you can return it within 30 days—as long as it's unused, in its original packaging, and in resellable condition. You’ll need to handle the return shipping, and once we receive and inspect it, we’ll refund the product cost (excluding shipping).
5. Refund Processing
Once we receive and approve your return, we’ll send a confirmation email and issue a refund to your original payment method within 7 business days. Please allow additional time for banks or credit card companies to process and reflect the refund.
If it’s been over 10 business days since your refund was approved and you still don’t see it, contact us at support@trailquestgear.com and we’ll look into it immediately.
6. Restocking Fees
In some cases, a restocking fee may apply depending on the item and return reason. If applicable, we’ll clearly communicate this during your return request process.

